PANASONIC 2.0HP CS-PV18TKH-1 (CU-PV18TKH-1) STANDARD NON-INVERTER AIR CONDITIONER

PANASONIC 2.0HP CS-PV18TKH-1 (CU-PV18TKH-1) STANDARD NON-INVERTER AIR CONDITIONER

Weight : 47 Kg

  • Airflow Direction Control (Up Down)
  • Manual Horizontal Airflow Direction Control
  • 24-Hour ON OFF Real Setting Timer
  • LCD Wireless Remote Control
  • Reliability Random Auto Restart (32 Restart Patterns)
  • Top-Panel Maintenance Access

EAN : CS-PV18TKH-1 (CU-PV18TKH-1) | SKU : CS-PV18TKH-1 (CU-PV18TKH-1)

Product Description

Refrigerant Type R410A

Cooling Capacity (min-max) kW 5.33

(min-max)Btu/h 18,200

EER (min-max) Btu/hW 9.73

Electrical Data Voltage (V) 230

Running Current (A) 8.3

Power Input (W) 1,870

Moisture Removal L/h 2.9

Pt/h 6.1

Air Circulation Indoor m3/min (ft3/min) 18.9 (667)

Outdoor m3/min (ft3/min) 35.2 (1,240)

Noise Level Indoor (H/L/Q-Lo) (dB-A) 43/39

Outdoor (H / L) (dB-A) 54

Dimensions Height (mm) 302 (619)

Height (inch) 11-29/32 (24-3/8)

Width (mm) 1,102 (824)

Width (inch) 43-13/32 (32-15/32)

Depth (mm) 244 (299)

Depth (inch) 9-5/8 (11-25/32)

Net Weight kg 12 (26)

lb 34 (75)

Refrigerant Pipe Diameter Liquid Side (mm) ø 6.35

Liquid Side (inch) 1/4

Gas Side (mm) ø 12.70

Gas Side (inch) 1/2

Pipe Extension Chargeless Pipe Length (m) 7.5

Maximum Pipe Length (m) 30

Maximum Elevation Length (m) 20

Additional Refrigerant Gas* (g/m) 20

Power Supply Indoor

Cleaner Air nanoe-G No

Odour-Removing Function Yes

Removable, Washable Panel Yes

Comfort iAUTO-X No

iAUTO Yes

ECONAVI No

Temperature Wave No

AUTOCOMFORT No

Inverter Control No

Quiet Mode Yes

Soft Dry Operation Mode Yes

Personal Airflow Creation No

Airflow Direction Control (Up Down) Yes

Manual Horizontal Airflow Direction Control Yes

Convenience 24-Hour Dual ON OFF Real Setting Timer No

24-Hour ON OFF Real Setting Timer Yes

LCD Wireless Remote Control Yes

Wired Remote Control Yes (Optional)

Reliability Random Auto Restart (32 Restart Patterns) Yes

Blue Fin Condenser 30m

Long Piping (Numbers indicate the maximum pipe length) Yes

Top-Panel Maintenance Access Yes

Self-Diagnostic Function No